FENKOM-SCM20 for Windor20



last update:
28.07.2008 12:51
Deutsch Deutsch English France Italiano

System file structure

Windor20 settings - Parameter description (date 03-01-2005)

General Description

1) A system file (e.g. IV-68) is used to describe all parts of the door or window, their manufacturing process and cycle names.

2) If there is only one manfacturing pass necessary, part description, parameter description and cycle names for up to two phases (manufacturing at end one and two) is in only one line.

3) If there is more than one manufacturing pass necessary, you have to define a seperate line for each required pass and phase with an assigned cycle name.

4) Special case: If there are additional passes necessary for one part, you have to increase the number of parts in the concerning line by the number of additional passes.

5) The cycle entries must be identical with the cycle names used on the machine.

Fields and parameters

Für den Aufbau der aktuellen Systemdatei gelten folgende Vorgaben und Vereinbarungen:
column value meaning
1 Sub-System (FEN = Windows, TUER = Doors)
FEN Window
TUER Door
2 Belongs to (R = jamb or F = Sash)
R jamb
F Sash
3 Identification of profil and position within jamb or sash
4 Reserve (presently not used)
5 Profile-heigth (presently not used, defined on machine)
6 Profile-Width (to be used for tenoning)
7 Type of processing on profile-termination-1 (tenoning for FASE-1)
8 Type of processing on profile-termination-2 (tenoning for FASE-2)
9 type of first measure: (AM, X, other on request)
AM external reference:
for sash-parts with position LI (=left), RE (=right), OB (=above), UN (=bottom) to define the distance between external edge of sash and external edge of jamb
for mullion and muntin to define for FASE-1 the distance of external edge of jamb or sash upto the left or bottom termination of respective par
X non applicable or without processing
10 value of first measure-type (FASE-1 or overlapping sash-parts)
11 type of second measure:
UE overlapping of "Stulp"-parts at double-sashed windows or doors when part-identification is LS or RS (left or right hung element). It determines the overlapping of the two sashes from the theoretical middle-line (+/-values)
AM reference from external-measure: like in col. 9 but for FASE-2
X non applicable or without processing
12 Value for second measure (FASE-2 or overlapping in double-sash)
13 Denomination of cycle, must be identical with cycle-name on machine

Sample file

===================================================================================
Columns:
1     2    3    4   5    6    7       8      9   10     11   12    13
===================================================================================
FEN   R    LI   0   67   80   ZA_UN   ZA_OB  X     0    X     0    RZo_RZu_Riso 
FEN   R    OB   0   67   80   SZ_LI   SZ_RE  X     0    X     0    RS_RS_Riso   
FEN   R    RE   0   67   80   ZA_UN   ZA_OB  X     0    X     0    RZo_RZu_Riso 
FEN   R    UN   0   67   80   SZ_LI   SZ_RE  X     0    X     0    RS_RS_Riu   
FEN   F    LI   0   67   80   SZ_UN   SZ_OB  AM   37    X     0    FS_FS_Fi  
FEN   F    LS   0   67   80   SZ_UN   SZ_OB  AM   37    UE   20    FS_FS_FiSt  
FEN   F    OB   0   67   80   ZA_LI   ZA_RE  AM   37    X     0    FZ_FZ_Fi   
FEN   F    RE   0   67   80   SZ_UN   SZ_OB  AM   37    X     0    FS_FS_Fi 
FEN   F    RS   0   67   80   SZ_UN   SZ_OB  AM   37    UE   20    FS_FS_FiSt 
FEN   F    UN   0   67   80   ZA_LI   ZA_RE  AM   63    X     0    FZ_FZ_Fi 
TUER  R    LI   0   67   80   ZA_UN   ZA_OB  X     0    X     0    RZo_RZu_Riso 
TUER  R    OB   0   67   80   SZ_LI   SZ_RE  X     0    X     0    RS_RS_Riso   
TUER  R    RE   0   67   80   ZA_UN   ZA_OB  X     0    X     0    RZo_RZu_Riso 
TUER  R    UN   0   67   80   SZ_LI   SZ_RE  X     0    X     0    RS_RS_Riu   
TUER  F    LI   0   67   80   SZ_UN   SZ_OB  AM   37    X     0    FS_FS_Fi  
TUER  F    LS   0   67   80   SZ_UN   SZ_OB  AM   37    UE   25    FS_FS_FiSt  
TUER  F    OB   0   67   80   ZA_LI   ZA_RE  AM   37    X     0    FZ_FZ_Fi   
TUER  F    RE   0   67   80   SZ_UN   SZ_OB  AM   37    X     0    FS_FS_Fi 
TUER  F    RS   0   67   80   SZ_UN   SZ_OB  AM   37    UE   25    FS_FS_FiSt 
TUER  F    UN   0   67   80   ZA_LI   ZA_RE  AM   63    X     0    FZ_FZ_Fi 
FEN   R    KV   0   67   80   ZA_UN   X      AM   47.5  X     0    Rko_Riso       
FEN   R    KV   0   67   80   X       ZA_OB  X     0    AM   47.5  Rku_Rku_Riso      
FEN   R    KU   0   67   80   ZA_LI   X      AM   44    X     0    Rko_Rko_Riso      
FEN   R    KU   0   67   80   X       ZA_RE  X     0    AM   44    Rko_Rko_Riu      
FEN   R    KO   0   67   80   ZA_LI   X      AM   44    X     0    Rko_Rko_Riso      
FEN   R    KO   0   67   80   X       ZA_RE  X     0    AM   44    Rko_Rko_Riso      
TUER  F    PH   0   67   80   ZA_LI   X      AM   57.5  X     0    FiK_FiK_Fi      
TUER  F    PH   0   67   80   X       ZA_RE  X     0    AM   57.5  FiK_FiK_Fi      
TUER  F    GU   0   67   80   ZA_LI   X      AM   57.5  AM    0    Fik_Laengs      
TUER  F    GU   0   67   80   X       ZA_RE  AM    0    AM   57.5  Fik_FiK_Fi     
===================================================================================
|     |    |    |   |    |    |       |      |     |    |     |      |
|     |    |    |   |    |    |       |	     |	   |	|     |	     --> cycle
|     |    |    |   |    |    |       |	     |	   |	|     --> value for Fase-2
|     |    |    |   |    |    |       |      |	   |    --> type of measure 
|     |    |    |   |    |    |       |	     |	   |        for Fase-2 or doulbe-sash:
|     |    |    |   |    |    |       |	     |	   |	    X  = not applicable
|     |    |    |   |    |    |       |	     |	   |	    UE = overlapping in "Stulp"
|     |    |    |   |    |    |       |	     |	   |	    AM = reference from external 
|     |    |    |   |    |    |       |	     |	   ---> value for Fase-1
|     |    |    |   |    |    |       |	     ---> type of measure for Fase-1
|     |    |    |   |    |    |       |		  or overlapping of sash to jamb
|     |    |    |   |    |    |       |		  X  = not applicable
|     |    |    |   |    |    |       |		  AM = reference from external
|     |    |    |   |    |    |       --> processing in Fase-2: X   = not applicable
|     |    |    |   |    |    |       	   SZ_OB = tenoning-above (for sashparts)
|     |    |    |   |    |    |            SZ_RE = tenoning-right (for jambparts)
|     |    |    |   |    |    |            ZA_OB = tenoning-above (for jambparts)
|     |    |    |   |    |    |            ZA_RE = tenoning-right (for sahparts)
|     |    |    |   |    |    --> processing in Fase-1: X  = not applicable
|     |    |    |   |	 | 		SZ_UN = tenoning-bottom (for sashparts)
|     |    |    |   |	 |	 	SZ_LI = tenoning-left (for jambparts)
|     |    |    |   |	 |		ZA_UN = tenoning-bottom (for jambparts)
|     |    |    |   |	 |		ZA_LI = tenoning-left (for sashparts)
|     |    |    |   |	 --> Profile-width
|     |    |    |   --> Profile-heigth
|     |    |	--> Reserve (for denominaltion of profile)
|     |	   --> Profile-Position: 
|     |    	LI, RE, OB, UN (left, right, above, bottom) - for sash and jamb
|     |	   	LS, RS - left-"Stulp" right-"Stulp" in double-sashed windows or doors
|     |		KV - mullion vertical;
|     |		KO - mullion horizontal with edge-above like jamb-above
|     | 	     used for fixed skylight  
|     |		KU - mullion horizontal with edge-above like jamb-bottom
|     |		     used for skylight with sash  
|     |		PH - muntin horizontal (presently only in sash of doors)
|     |		GU - internal bottom-spacer (presently only in sash of doors)
|     --> belongs R or F in Sub-System:  R = jamb,  F = sash
--> SUB-System within main-system (presently only FEN = Windows, TUER = Doors)